Analysis of common failures of servo motors

作者:admin 日期:2020-11-27 瀏覽:145

1. The motor generates shaft current




The current in the circuit of shaft bearing pedestal base of motor is called shaft current.




Causes of shaft current:




1) The magnetic field is asymmetric;




2) There is a wave in the supply current;




3) The air gap is uneven due to the rotor eccentricity due to poor manufacturing and installation;




4) The two semicircles of the detachable stator core have gaps;




5) The number of stator cores with fan-shaped lamination is not suitable.




2. The motor is not suitable for light load operation




When the motor runs under light load, it will cause:




1) The motor power factor is low;




2) Low efficiency of motor will cause waste of equipment and uneconomical operation.




3. Causes of motor overheating




1) Excessive load;




2) Missing items;




3) The air duct is blocked;




4) Low speed running time is too long;




5) The power supply has too large wave.




4. Causes of unbalanced three phase current of motor




1) The three-phase voltage is unbalanced;




2) Bad welding or bad contact of a phase branch in the motor




3) Motor winding turn to turn short circuit or phase to phase short circuit to ground;




4) Wrong wiring.